QUICK REFERENCE
35
ARB
ARB – Add Built-In Waveform
Example: ARB Mode, Exponential Rise. Start 0, Length 100, Scale
32767.
Output
1. Press ARB, Built in
(F3), More (F5), Exp
Rise (F1).
2. Press Start (F1), 0 +
Enter (F5), Return
(F6).
3. Press Length (F2),
100, Enter (F5),
Return (F6).
4. Press Scale (F3),
32767, Enter (F5),
Return (F6), Done
(F4).
ARB – Add Built-In Waveform - Pulse
Example: ARB Mode, Pulse. Start 0, Frequency 1kHz, Duty 25%.
Output
5. Press ARB, Built in
(F3), More (F5), Exp
Rise (F1).
6. Press Freq.(F1),1,
kHz (F5), Return
(F6).