Note
When using sine, square, triangle or ramp
waveforms, 0˚ is the point where the waveforms
are at zero volts.
0˚ is the starting point of a waveform. For sine,
square or Triangle, Ramp waveforms, 0˚ is at 0
volts (assuming there is no DC offset).
Burst Phase is used for both N cycle and Gated
burst modes. In gated burst mode, when the
Trigger INPUT signal goes low the output is
stopped after the current waveform is finished.
The voltage output level will remain equal to the
voltage at the starting burst phase.
Burst Trigger Source
Each time the function generator receives a trigger in triggered burst
(N-Cycle) mode, a waveform burst is output. The number of
waveforms in each burst is designated by the burst cycle (burst
count). When a burst has completed, the function generator waits for
the next trigger. Internal source is the default triggered burst (N-
cycle) mode on power up.
Panel Operation
1. Press the Burst key.
2. Press F1 (N Cycle).
3. Press F5 (TRIG setup).
4. Choose a trigger type by
pressing F1 (INT), F2 (EXT)
or F3 (Manual).
~