Sine Squ Tri Ramp
Pulse Noise
ARB
AM
FM
PWM
FSK
SWEEP
BRUST
Syntax SOURce[1]:FUNCtion {SINusoid|SQUare|RAMP|
PULSe|NOISe|TRIAngle|DC| USER}
Example SOUR1:FUNC SIN
Sets the output as a sine function.
Query Syntax SOURce[1]:FUNCtion?
Return Parameter SIN, SQU, RAMP, PULS,
NOIS, DC, TRI, USER
Returns the current output
type.
Example SOUR1:FUNC?
SIN
Current output is sine.
SOURce[1]:FREQuency
Source Specific
Command
Description
Sets the output frequency for the
SOURce[1]:FUNCtion command. The query
command returns the current frequency setting.
Note
The maximum and minimum frequency depends
on the function mode.
Sine, Square
1μHz~80MHz(3081)/
50MHz(3051)
Ramp, Triangle
1μHz~80MHz(3081)/
50MHz(3051)
Pulse
50μHz~50MHz
Noise, DC
Not applicable