REMOTE INTERFACE
217
Sets the duty cycle to the highest possible for the
current frequency.
Query Syntax SOURce[1]:SQUare:DCYCle? {MINimum|MAXimum}
Return Parameter <NR3> Returns the duty cycle as a
percentage.
Example SOUR1:SQU:DCYC?
+5.00E+01
The duty cycle is set 50%.
SOURce[1]:RAMP:SYMMetry
Source Specific
Command
Description
Sets or queries the symmetry for ramp waves only.
The setting is remembered if the function mode is
changed. The default symmetry is 50%.
Note
For ramp waveforms, the Apply command and
AM/FM modulation modes ignore the current
symmetry settings.
Syntax SOURce[1]:RAMP:SYMMetry {< percent>
|MINimum|MAXimum}
Example SOUR[1]:RAMP:SYMM MAX
Sets the symmetry to the 100%.
Query Syntax SOURce[1]:RAMP:SYMMetry?
{MINimum|MAXimum}
Return Parameter <NR3> Returns the symmetry as a
percentage.
Example SOUR1:RAMP:SYMMetry?
+1.0000E+02
The symmetry is set as 100%.