Gw-instek AFG-3000 Series User Manual Page 277

  • Download
  • Add to my manuals
  • Print
  • Page
    / 304
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 276
REMOTE INTERFACE
277
An unexpected character string was used where
none were expected. Example: A character string is
used instead of a valid parameter.
SOURce1:SWEep:SPACing ’TEN’
-161 Invalid block data
Invalid block data was received. Example: The
number of bytes sent with the DATA:DAC
command doesn’t correlate to the number of bytes
specified in the block header.
-168 Block data not allowed
Block data was received where block data is not
allowed. Example:
SOURce1:BURSt: NCYCles #10
-170~178 expression errors
Example: The mathematical expression used was not
valid.
Execution Errors
-211 Trigger ignored
A trigger was received but ignored. Example:
Triggers will be ignored until the function that can
use a trigger is enabled (burst, sweep, etc.).
-223 Too much data
Data was received that contained too much data.
Example: An arbitrary waveform with over 1,048,576
points cannot be used.
-221 Settings conflict; turned off infinite burst to allow immediate trigger
source
Example: Infinite burst is disabled when an
immediate trigger source is selected. Burst count set
to 1,000,000 cycles.
Page view 276