PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL ⎯ ⎯iCONTENTS PAGE1. PRODUCT INTRODUCTION ...
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯13Figure 4-1 Front PanelPSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯14Figure 4-2 Rear Pa
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯155. OPERATION INSTRUCTION5-1. Basic Operationz The applied Voltage/Current Unit for this series
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯17The minimum resolution of output voltage is at 1mV. When set outputto ON, press [V SET] to proc
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯19When the current load runs through output terminal, if the currentexceeds the setting value, th
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯21z OCP DELAY TIME CHARTRemark: When the over current protection of the instrument istriggered,
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯23z DELAY : The Auto mode setting for the voltage/current Delay timeSetting method: Press [SHIFT
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯25z AUTO RANGEAUTO RANGE Setting method: Press [SHIFT][AUTO RANGE] , useknob to select the item
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯27z STORE : Save the setting data to one of the memory groupsSTORE setting method: Press the fun
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯29For example: Select RS-232 communication interface and set the BAUDrate to 9600.Press [SHIFT] [
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯31z V STEP : The step setting of voltage.Set the maximum value of Step to be the rating value of
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL ⎯ ⎯iiiSAFETY TERMS AND SYMBOLSThese terms may appear in this manual or on the product:WARNING
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯335-3. Operation MethodThe applied Voltage/Current Unit for this series instruments is Volt andAm
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯354) Set the desired output current value:Press [I SET], the panel operation is set to current va
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯372) Store the present setting status to the memory bank:Press [SHIFT][STORE], set the panel ope
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯39z The flow chart of the Auto Running OperationPSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯41Figure 5-2: Sampling and wiring application for the output terminal ofEuropean Regulation1) C
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯435-4. The maximum value of the output settingModelPSM-2010 PSM-3004 PSM-6003Output RangeItem8V,2
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯456. MAINTENANCEThe following instructions are executed by qualified personnel only. Toavoid elec
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯472) The calibrated devices:For general calibration, user can select the suitable calibration de
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯496-4. Adjustment and Calibration--Preparation1. 30 minutes warm up before calibration.2. Ambie
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯51Note: The DMM selected for the measurement must have the resolution of4 digits after the decima
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL ⎯ ⎯vThis cable/appliance should be protected by a suitably rated andapproved HBC mains fuse:
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯53Now, switch to SAVE by using the knob and press [ENTER] to leave themode with storing. Also
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯557. THE SYSTEM DIAGRAM AND DESCRIPTION7-1. Block DiagramThe graph above is the system diagram of
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL11. PRODUCT INTRODUCTION1-1. DescriptionPSM-series Programmable Power Supply is controlled by Micro Pro
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯32. TECHNICAL SPECIFICATIONSSpecification PSM-2010 PSM-3004 PSM-6003Low Range 0~ +8V / 0~20A 0~ +
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯5Specification PSM-2010 PSM-3004 PSM-6003Voltage 0.02% + 1mVCurrent 0.1% + 1mAMemory Store/Recall
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯7WARNING. To avoid personal injury, disconnect the powercord before removing the fuse holder.3-3
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯915.DELAYSet the voltage and current output time in theautomatic operation mode.16.AUTO RANGE(AUT
PSM-SERIES PROGRAMMABLE POWER SUPPLYUSER MANUAL⎯ ⎯114-3. Display brief1. AdrsSet the power supply to the address of Listen orTalk by using the inte
Comments to this Manuals