Gw-instek LCR-914 User Manual

Browse online or download User Manual for Equipment Gw-instek LCR-914. GW Instek LCR-914 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Hand-held LCR Meter
LCR-914/915/916 Series
USER MANUAL
GW INSTEK PART NO. 82CR-91600MA1
ISO-9001 CERTIFIED
MANUFACTURER
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Hand-held LCR Meter

Hand-held LCR Meter LCR-914/915/916 Series USER MANUAL GW INSTEK PART NO. 82CR-91600MA1 ISO-9001 CERTIFIED MANUFACTURER

Page 2

LCR-914/915/916 User Manual 8 Making 4-Wire Measurements with the 5-Wire Terminal Making 2-Wire Measurements with the Alligator Clip Set

Page 3 - Warning

LCR-914/915/916 User Manual 9 Measuring L/C/R/DCR • Press the L/C/R/DCR button to select the measurement function. • Press the L/C/R/DCR button

Page 4 - Instruction Manual

LCR-914/915/916 User Manual 10 Measuring D/Q/ESR/θ • Press the D/Q/ESR/θbutton to select the measurement function.

Page 5 - Meter Description

LCR-914/915/916 User Manual 11 Selecting the Test Frequency • Press the FREQ button to select the test frequency. • The selectable frequency r

Page 6 - Package Contents

LCR-914/915/916 User Manual 12 Selecting the Series / Parallel Measurement Function • At the L/C/R measuring function, it defaults to Auto Se

Page 7

LCR-914/915/916 User Manual 13 Selecting the Display Count • Press the 2000 /20000 button to select the display count. Zero The Zero

Page 8 - Phase Drawing

LCR-914/915/916 User Manual 14 Display Hold • Press the HOLD button to hold the reading on the meter, press the button again to return. D

Page 9

LCR-914/915/916 User Manual 15 Calibratation In order to achieve the best measurement results, calibration is essential. To calibrate the meter,

Page 10

LCR-914/915/916 User Manual 16 When “OPEn” appears on the sub display, make the terminal or the SMD test probe open, and press t

Page 11 - Measuring L/C/R/DCR

LCR-914/915/916 User Manual 17 When “Srt” appears on the sub display, short the terminals or the SMD test probe, and then press the CAL button to

Page 12 - Measuring D/Q/ESR/θ

This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied,

Page 13 - LCR-914: 100Hz, 120Hz, 1kHz

LCR-914/915/916 User Manual 18 Sorting To check the accuracy of a part, press the SORTING button to enter the sorting mode. The sorting result a

Page 14

LCR-914/915/916 User Manual 19 The default sorting standard value is the current value, and the default tolerance is ±1.0%. Setup Sorting

Page 15 - Selecting the Display Count

LCR-914/915/916 User Manual 20 Battery Replacement Refer to the following figure to replace the batteries : External Power Sour

Page 16 - Display MAX/MIN

LCR-914/915/916 User Manual 21 Specifications General Specifications Maximum voltage applied to any terminal: 30VDC or 30VAC rms Display: 2000/

Page 17 - Calibratation

LCR-914/915/916 User Manual 22 Shock Vibration: Sinusoidal vibration per MIL-T- 28800E (5 ~ 55 Hz, 3g maximum). Drop Protection: 4 feet drop to h

Page 18

LCR-914/915/916 User Manual 23 (4) Inductance Frequency Range Accuracy 100Hz 120Hz 20.000mH ± (0.5% + 5d) [2] 200.00mH ± (0.2% + 2d) 2000.0mH 20.

Page 19

LCR-914/915/916 User Manual 24 (5) Capacitance Frequency Range Accuracy 100Hz 120Hz 2000.0pF ± (0.5% + 5d) [2] 20.000nF ± (0.2% + 2d) 200.00nF 2000

Page 20 - Sorting

LCR-914/915/916 User Manual 25 (6) Resistance Frequency Range Accuracy 100Hz 120Hz 200.00Ω ± (0.2% + 5d) 2.0000kΩ ± (0.2% + 2d) 20.000kΩ 200.00kΩ 2

Page 21 - Setup Sorting Standard

LCR-914/915/916 User Manual 26 (7) DCR Range Resolution Accuracy 200.00Ω 0.01Ω ± (0.2% + 5d) 2.0000kΩ 0.0001kΩ ± (0.2% + 2d) 20.000kΩ 0.001kΩ 200.0

Page 22

LCR-914/915/916 User Manual 1 Read First Safety Information Understand and follow the operating instructions carefully. Use the meter only

Page 23 - Specifications

LCR-914/915/916 User Manual 2 CAUTION ˙ Never connect a source of voltage that could result in damage to the meter and the equipment under tes

Page 24 - Electrical Specifications

LCR-914/915/916 User Manual 3 Meter Description Front Panel Illustration 1. LCD display: 20000/2000 counts. 2. Function buttons. 3. 5

Page 25

LCR-914/915/916 User Manual 4 Package Contents 1. 5V AC Adapter (only LCR-916). 2. USB Cable (only LCR-916). 3. Shorting Cube. 4. SMD Test Probe

Page 26

LCR-914/915/916 User Manual 5 Measuring Principles tanD1QRXXtanC1fC21XLfL2XRXXtan)X(XRZ)Xj(XRECL1CLCL1CL2CL

Page 27

LCR-914/915/916 User Manual 6 Phase Drawing

Page 28

LCR-914/915/916 User Manual 7 Making 5-Wire Measurements with the SMD Test Probe