Gw-instek AFG-3000 Series User Manual Page 221

  • Download
  • Add to my manuals
  • Print
  • Page
    / 304
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 220
REMOTE INTERFACE
221
Pulse Configuration Commands
The pulse chapter is used to control and output pulse waveforms.
Unlike the APPLy command, low level control is possible including
setting the rise time, fall time, period and pulse width.
SOURce[1]:PULSe:PERiod
Source Specific
Command
Description
Sets or queries the pulse period. The default period
is 1 ms.
Note
The pulse period must be greater than the pulse
width and edge time(1.6x) combined.
Pulse Width + (1.6 * Edge Time) < Period
If the edge time or pulse width are too great, they
will automatically be reduced to fit the period by
the function generator.
The PULSe:PERiod function will change the period
for all functions, not just for the pulse waveforms.
If a different function is chosen and the current
period is out of range, the period will be
automatically adjusted to suit the new function.
Syntax SOURce[1]:PULSe:PERiod
{<seconds>|MINimum|MAXimum}
Example SOUR1:PULS:PER MIN
Sets the period to the minimum time allowed.
Query Syntax SOURce[1]:PULSe:PERiod? [MINimum|MAXimum]
Return Parameter <seconds> 20 ns ~ 2000 seconds
Page view 220