PPH-1503 User Manual
134
Specifications
The specifications apply under the following conditions: The PPH-1503
is powered on for at least 30 minutes, within +18°C~+28°C.
DC GENERAL
MEASUREMENT TIME CHOICES
0.01 ~ 10PLC
1
,0.01PLC/step
AVERAGE READINGS
1~10
TYPICAL READING TIME
2,3
31ms
DC VOLTAGE
OUTPUT
(23±5)
OUTPUT VOLTAGE
0~15V
OUTPUT ACCURACY
± (0.05%+10mV)
PROGRAMMING RESOLUTION
2.5mV
READBACK ACCURACY
3
± (0.05%+3mV)
READBACK RESOLUTION
1mV
OUTPUT VOLTAGE RISING TIME
0.15ms (10% ~ 90%)
OUTPUT VOLTAGE FALLING TIME
0.65ms (90% ~ 10%)
LOAD REGULATION
0.01%+2mV
LINE REGULATION
0.5mV
STABILITY
4
0.01%+0.5mV
RECOVERY TIME(1000%LOAD
CHANGE)
<40us (<100mV)
<80us (<20mV)
RIPPLE AND NOISE
5
1mV rms(0~1MHz)
8mVpp(20Hz~ 20MHz)
DC CURRENT
(23±5)
OUTPUT CURRENT
0 ~ 5A (0 ~ 9V)
0 ~ 3A (9 ~ 15V)
SOURCE COMPLIANCE ACCURACY
±(0.16%+5mA)
PROGRAMMED SOURCE
RESOLUTION
1.25mA
READBACK ACCURACY
3
5A range: ±(0.2%+400uA)
5mA range: ±(0.2%+1uA)
READBACK RESOLUTION
5A range: 100uA
5mA range: 0.1uA
CURRENT SINK CAPACITY
0 ~ 5V: 2A
5 ~ 15V:(2A derate 0.1A)/V
LOAD REGULATION
0.01%+1mA
LINE REGULATION
0.5mA
STABILITY
4
0.01%+50uA
DVM
INPUT VOLTAGE RANGE
0 ~ 20VDC
INPUT IMPEDANCE
10
11
Ω
MAXIMUM INPUT VOLTAGE
-3V, +22V
READING ACCURACY
3
± (0.05%+3mV)
READING RESOLUTION
1mV
PULSE CURRENT
MEASUREMENT
TRIGGER LEVEL
5mA ~ 5A, 5mA/step
HIGH TIME/LOW TIME/AVERAGE
TIME
33.3us to 833ms, 33.3us/step
TRIGGER DELAY
0 ~ 100ms,10us/steps
AVERAGE READINGS
1 ~ 100