90
:SYSTem:CONFigure:PROTection:RECovery
Set
Query
Description
Syntax
Return Syntax
Parameter
SAFE
The output is not turned on automatically
when the cause of the alarm is fixed.
AUTO
The output is turned on automatically
when the cause of the alarm is fixed.
:SYSTem:CONFigure:MSLave
Set
Query
Description
Syntax
Query Syntax
Parameter/Return
<NR1>
Description
0
Master/Local
1
Master/with 1 unit in Parallel (total:2 units)
2
Master/with 2 units in Parallel (total: 3 units)
3
Master/with 3 units in Parallel (total: 4 units)
4
Slave
:SYSTem:CONFigure:OUTPut:EXTernal
[:MODE]
Set
Query
Description
Syntax
Query Syntax