Gw-instek GPD-4303S User Manual

Browse online or download User Manual for Equipment Gw-instek GPD-4303S. GW Instek GPD-4303S User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - DC Power Supply

DC Power Supply GPD-X303S Series USER MANUAL GW INSTEK PART NO. 82PD-433S0M01 ISO-9001 CERTIFIED MANUFACTURER

Page 2

GPD-X303S Series User Manual OVERVIEW This chapter describes the GPD-2303S/GPD-3303S/GPD-4303S series in a nutshell, including its main features a

Page 3 - Table of Contents

OVERVIEW Independent / Track ing Seri es / Tracking Parallel The three output modes of GPD-X303S series, independent, tracking series, and tracking

Page 4

GPD-X303S Series User Manual Dynamic load When used in audio production lines, the power supply can provide a continuous or dynamic load using a j

Page 5 - SAFETY INSTRUCTIONS

OVERVIEW Series Lineup / Main Features Main Features Performance • Low noise: Temperature controlled cooling fan • Compact size, light weight O

Page 6 - Safety Guidelines

GPD-X303S Series User Manual Principle of Operation Overview The power supply consists of the following. • AC input circuit • Transformer • Bi

Page 7

OVERVIEW Auxiliary Rectifier The auxiliary rectifiers D1011~ D1014 provide bias voltage filtered by the capacitors C102 and C103, for the pre-regul

Page 8

GPD-X303S Series User Manual Front Panel Overview VoltMeter Ammeter Memory KeysVoltageKnobsCurrentKnobsParallelKeysCH1/CH3, CH2/CH4(Beep) KeysOutp

Page 9 - SAFETY INSTRUCTIONS

OVERVIEW Control Panel Memory Keys Saves or recalls panel settings. Four settings, 1 ~ 4, are available. For save/recall details, see page41.

Page 10 - OVERVIEW

GPD-X303S Series User Manual Voltage Knobs Adjusts the output voltage level for the selected channel. Pressing the knob switches coarse and fine

Page 11

OVERVIEW Terminals Default Terminals European Terminals GND Terminal Accepts a grounding wire. CH1 CV/CC Indicator Indicates CH1 Constant

Page 12

This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual may be photocopied,

Page 13 - Main Features

GPD-X303S Series User Manual CH3 Overload Indicator Indicates when CH3 (3303S) output current is overloaded. CH3 Voltage Selector Selects CH3 ou

Page 14 - Principle of Operation

OVERVIEW Rear Panel Overview USB Connector Accepts a USB slave connector for command-based remote control (page43). Power Cord / Fuse Socket T

Page 15

GPD-X303S Series User Manual CV/CC Crossover Characteristics Background The GPD-4303S, GPD-3303S and GPD-3303S automatically switch between cons

Page 16 - Front Panel Overview

SETUP SETUP This chapter describes how to properly power up and configure the GPD-X303S series before operation. Power Up Select AC voltage Before

Page 17

GPD-X303S Series User Manual Load Cable Connection GTL-104A 1. Turn the terminal counterclockwise and loosen the screw. 2. Insert the cable ter

Page 18

SETUP Output On/Off Panel operation Pressing the Output key turns on all channel outputs. The key LED also turns on. Pressing the Output key aga

Page 19

GPD-X303S Series User Manual Switch between channels Panel operation Switching between channels only applies to GPD-4303S. Press the CH1/3 ke

Page 20

OPERATION OPERATION CH1/CH2 Independent Mode Background / Connection CH1 and CH2 outputs work independent of each other. Output rating 0 ~ 30V/0

Page 21 - Rear Panel Overview

GPD-X303S Series User Manual Note: this diagram shows non-European terminals. 3. Set the CH1 output voltage and current. Press the CH1 key (LE

Page 22

OPERATION CH3 Independent Mode Background / Connection For the GDP-3303S the CH3 rating is fixed at 2.5V/3.3V/5V, 3A. CH3 for the 4303S is variabl

Page 23 - Power Up

TABLE OF CONTENTS Table of Contents SAFETY INSTRUCTIONS ... 5 OVERVIEW...

Page 24 - Load Cable Connection

GPD-X303S Series User Manual 2. 3303S: Select the output voltage, 2.5V/3.3V/5V using the CH3 voltage selector key. 4303S: Press the CH1/3 key to

Page 25 - Output On/Off

OPERATION CH4 Independent Mode Background / Connection The GPD-4303S has a rating of 5V/1A max. Output rating 5V/1A max No Tracking Series/Para

Page 26 - Front Panel Lock

GPD-X303S Series User Manual 3. To turn on the output, press the output key. The key LED turns on. CV → CC When the output value exceeds the se

Page 27 - OPERATION

OPERATION CH1/CH2 Tracking Series Mode Background Tracking series operation doubles the Voltage capacity of the GPD-X303S series by internally con

Page 28

GPD-X303S Series User Manual Note: this diagram shows non-European terminals. 3. Press the CH2 key (LED turns on) and then use the Current kno

Page 29 - CH3 Independent Mode

OPERATION Voltage level Double the reading on the CH1 Voltage meter. In the above case, the actual output is 20.0 x 2 = 40.0V. Current level

Page 30

GPD-X303S Series User Manual 1. Press the SER/INDEP key to activate the tracking series mode. The key LED turns on. 2. Connect the load to th

Page 31 - CH4 Independent Mode

OPERATION 5. To turn on the output (and LED), press the output key. 6. For the master (CH1) output level and CV/CC status, refer to the CH1 me

Page 32

GPD-X303S Series User Manual Slave (CH2) voltage level The CH1 meter reading shows the output voltage. In the above case, 20.0V. Slave (CH2) c

Page 33 - CH1/CH2 Tracking Series Mode

OPERATION CH1/CH2 Tracking Parallel Mode Background / Connection Tracking parallel operation doubles the current capacity of the GPD-X303S series

Page 34

GPD-X303S Series User Manual 4 Remote Connection Step... 44 Command Syntax ... 46 Error Messages

Page 35

GPD-X303S Series User Manual 3. To turn on the output, press the output key. The key LED turns on. 4. The CH2 C.V./C.C. PAR. indicator turns

Page 36

SAVE/RECALL SETUP SAVE/RECALL SETUP Save Setup Background The front panel settings can be stored into one of the four internal memories. Contents

Page 37

GPD-X303S Series User Manual Recall Setup Background The front panel settings can be recalled from one of the four internal memories. Contents Th

Page 38

REMOTE CONTROL REMOTE CONTROL Remote Control Setup Background The GPD-X303S is capable of being remotely controlled via a USB connection. Interfac

Page 39

GPD-X303S Series User Manual Remote Connection Step Entering the remote control mode 1. Connect the USB cable to the slave port. 2. The connect

Page 40

REMOTE CONTROL 4. The power supply goes back to the local operation mode. 45

Page 41 - SAVE/RECALL SETUP

GPD-X303S Series User Manual Command Syntax Command format ISET<X>:<NR2>NL12345 1: command header 2: output channel 3: separator 4: p

Page 42 - Recall Setup

REMOTE CONTROL e Command not allowed The entered command is not allowed in the circumstance. Example: trying to set CH2 output while in the trackin

Page 43 - REMOTE CONTROL

GPD-X303S Series User Manual Command Details ISET<X>:<NR2> Description Sets the output current for the selected channel. X 1= CH1, 2=

Page 44 - Remote Connection Step

REMOTE CONTROL VSET<X>? Description Returns the output voltage setting. X 1: CH1, 2: CH2, (4303S: 3: CH3, 4: CH4) Response time Minimum 10m

Page 45

SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS This chapter contains important safety instructions that you must follow when operating the GPD-X303S series

Page 46 - ISET<X>:<NR2>NL

GPD-X303S Series User Manual BEEP<Boolean> Description Turns the beep on or off. <Boolean> 0:off, 1:on Response time Minimum 10ms Exa

Page 47 - Command List

REMOTE CONTROL Return parameter GW INSTEK,GPD-X3303,SN: xxxxxxxx, Vx.xx (Manufacturer, model name, serial number, firmware version) RCL<NR1>

Page 48 - Command Details

GPD-X303S Series User Manual Response time Minimum 10ms ERR? Description Checks the error status of the instrument and returns the last error mes

Page 49 - TRACK<NR1>

FAQ FAQ Q1. I pressed the panel lock key but the output still turns on/off. A1. For safety reasons the output key is not affected by the panel key

Page 50 - STATUS?

GPD-X303S Series User Manual APPENDIX Fuse Replacement Steps 1. Take off the power cord and remove the fuse socket using a minus driver. 2.

Page 51 - BAUD<NR1>

APPENDIX Specifications The specifications apply when the GPD-X303S series are powered on for at least 30 minutes under +20°C – +30°C. Output Rati

Page 52

GPD-X303S Series User Manual Voltmeter 32V full scale, 5 digits 0.4" LED display Program Accuracy Voltage: ± (0.03% of reading + 10mV) C

Page 53

APPENDIX Declaration of Conformity We GOOD WILL INSTRUMENT CO., LTD. (1) No.7-1, Zhongxing Rd., Tucheng Dist., xinbei City 236, Taiwan (2) No. 69

Page 54 - APPENDIX

GPD-X303S Series User Manual INDEX Automatic out off ...25 Banana plug ...24 Baud rate Remote control...

Page 55 - Specifications

INDEX 59 FAQ ...53 manual ...25 Remote ...50 Output voltag

Page 56 - Options

GPD-X303S Series User Manual Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contac

Page 57 - Declaration of Conformity

SAFETY INSTRUCTIONS Fuse WARNING • Fuse type: 100V/120V: T6.3A/250V, 220V/230V: T3.15A/250V • Make sure the correct type of fuse is installed bef

Page 58

GPD-X303S Series User Manual (Pollution Degree) EN 61010-1:2001 specifies the pollution degrees and their requirements as follows. The GPD-X303S

Page 59

SAFETY INSTRUCTIONS Power cord for the United Kingdom When using the GPD-2303S/GPD-3303S/GPD-4303S series in the United Kingdom, make sure the power

Related models: GPD-3303S | GPD-2303S |

Comments to this Manuals

No comments