DC Power Supply SPD-3606 USER MANUAL GW INSTEK PART NO. 82PD-36060M0 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary informat
SETUP 19 SETUP This chapter describes how to properly power up and configure SPD-3606 before the operation. For checking the functionality, refer t
SETUP 21 Power Up Power On Press the Power switch to turn On the power. The CH1/CH2 indicators and meters turn On. VOLTAGECURRENTCH1MASTERC.V.C.
SETUP 23 * When setting the OVP for channel3, select CH3 meter using the CH1/CH3 meter switch. CH1CH3 5. When finished, slide the rear panel swi
SETUP 25 Output On/Off Panel operation Pressing the Output key once Turns On the output, all channels 1/2/3 at once. OUTPUTON / OFFOUTPUTON / OFF
OPERATION 27 2. Set the tracking switch position to INDEP, + . TRACKINGINDEP.SERIESPARALLEL 3. Set the OVP if necessary. For details, see pag
OPERATION 29 2. Set the OVP if necessary. For details, see page22. O.V.P.SETTRIP 3. Connect the load to the front panel channel3 +/− terminal.
OPERATION 31 2. Set the tracking switch position to Series, + . TRACKINGINDEP.SERIESPARALLEL 3. Set the OVP if necessary. In tracking series
OPERATION 33 Tracking series with common terminal Connection CH2CH1LOADCOM Output rating 0~60V/0~3A or 0~30V/0~6A for CH1 ~ COM 0~–60V/0~3A or 0~–
OPERATION 35 6. Set the output Current separately, using both the Channel1 (Master) and Channel2 (Slave) Current knob. VOLTAGECURRENTCH1MASTERC.V
OPERATION 37 3. Set the OVP if necessary. In tracking parallel mode, set the Channel2 (Slave) OVP setting to the maximum level, so that the OVP t
TABLE OF CONTENTS 3 Table of Contents SAFETY INSTRUCTION ... 5 OVERVIEW...
REMOTE OUTPUT CONTROL 39 REMOTE OUTPUT CONTROL Background The remote control terminal on the rear panel can turn the output On/Off, just like t
PERFORMANCE VERIFICATION 41 Default SPD-3606 setting The following is the required front and rear panel setting before running each verification. R
PERFORMANCE VERIFICATION 43 5. Turn On the SPD output. OUTPUTON / OFFOUTPUTON / OFF Minimum output Voltage 6. Record the Multimeter reading as th
PERFORMANCE VERIFICATION 45 Tracking Series Voltage Verification Check item • Minimum output Voltage accuracy • Maximum output Voltage accuracy C
PERFORMANCE VERIFICATION 47 Output Current verification Check item • Minimum output Current accuracy • Maximum output Current accuracy • Current
PERFORMANCE VERIFICATION 49 11. Connect the Multimeter to SPD Channel3 and repeat step 4, 5, 8, 9. CH1CH3CH30.1 5V, 3A * Skip step 6 and 7 since
PERFORMANCE VERIFICATION 51 Minimum OVP setting 6. Record the SPD Voltage meter reading as the Minimum OVP setting accuracy. Here is the acceptanc
PERFORMANCE VERIFICATION 53 19. Turn On the SPD output. OUTPUTON / OFFOUTPUTON / OFF 20. Slowly turn up the SPD Voltage knob until the OVP indicat
PERFORMANCE VERIFICATION 55 Output current verification (Minimum/Maximum) Item Channel Min. limit Result Max. limit CH1 –1mA 0mA Minimum
APPENDIX 57 APPENDIX Fuse Replacement Step 1. Take off the power cord and remove the fuse socket using a minus driver. BEFORE REPLACING FUSEDIS
SAFETY INSTRUCTION 5 SAFETY INSTRUCTION This chapter contains important safety instructions that you must follow when operating SPD-3606 and when ke
APPENDIX 59 Specification Output Ratings CH1/CH2 Independent 0 ~ 30V / 0 ~ 6A 0 ~ 60V / 0 ~ 3A CH1/CH2 Series 0 ~ 60V / 0 ~ 6A 0 ~ 120V / 0 ~ 3A
APPENDIX 61 Declaration of Conformity We GOOD WILL INSTRUMENT CO., LTD. (1) No.7-1, Jhongsing Rd., Tucheng City, Taipei County, Taiwan (2) No. 69,
INDEX 63 manual... 25 remote... 39 response time spec ...
SAFETY INSTRUCTION 7 • To ensure fire protection, replace the fuse only with the specified type and rating. • Disconnect the power cord before fu
OVERVIEW 9 OVERVIEW This chapter describes SPD-3606 in a nutshell, including its main features and front / rear panel introduction. After going thr
OVERVIEW 11 Principle of Operation Block diagram Power supply converts the AC mains into DC Power source for internal units. Channel 1/2/3 control
OVERVIEW 13 CH1/2/3 Controller The Controller for Channel 1, 2, and 3 takes care of the interface between SPD-3606 and users. Several sub-units co
OVERVIEW 15 CH2 meter Displays Channel2 current (A) and voltage (V). CH2 Tracking mode switches TRACKINGINDEP.SERIESPARALLEL Activates and selects
OVERVIEW 17 Rear Panel Overview BEFORE REPLACING FUSEDISCONNECT POWER CORDWARNING23 0VFUSE RATINGAS SPECIFIED250 VT10AREPLACE FUSE11 5VAC50/ 60 Hz5
Comments to this Manuals