Digital Oscilloscope & Multimeter
GDS-122
USER MANUAL
GW INSTEK PART NO.
ISO-9001 CERTIFIED MANUFACTURER
2012edition
This manual contains proprietary information, which is protected by
copyrights. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent of Good Will company.
The information in this manual was correct at the time of printing.
However, Good Will continues to improve products and reserves the
rights to change specification, equipment, and maintenance procedures
at any time without notice.
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Good Will Instrument Co., Ltd.
No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan
March
Page view 0
1 2 3 4 5 6 ... 51 52

Summary of Contents

Page 1 - USER MANUAL

Digital Oscilloscope & Multimeter GDS-122 USER MANUAL GW INSTEK PART NO. ISO-9001 CERTIFIED MANUFACTURER  2012editionThis manual contai

Page 2 - TABLE OF CONTENTS

Using the Oscilloscope 19 Example Before After22B4. Introducing the display contents Trigger statusVertical center positionVertical scaleTrigger le

Page 3 - SAFETY INSTRUCTIONS

Using the Oscilloscope 21 24B6. Adjusting waveform positions Selecting the menu PresstheOSCOPTIONkeyrepeatedlyuntilthefollowingmenuappears

Page 4

Using the Oscilloscope 23 Setting the vertical position 1. PresstheOSCOPTIONkeyrepeatedlyuntilthefollowingmenuappearsonthedisplay.–

Page 5 - GETTING STARTED

Using the Oscilloscope 25 MENUCH1 SETUPCH2 SETUPOFFInvertedONF4 Invert off Invert on Selecting the magnification 1. PresstheMENUkeyandusethe

Page 6 - Main Features

Using the Oscilloscope 27 27BConfiguring trigger settings: general settings Overview Thetriggersettingsconfigurehowtheincomingsignalistrigg

Page 7 - Manual Overview

Using the Oscilloscope 29 Usethearrowkeystochangethetriggeringposition.Move the trigger point upMove the trigger point downMove the trigge

Page 8 - OSCILLOSCOPE

Using the Oscilloscope 31  Example: falling edge Triggering pointFalling edge Selecting the source channel PressF3(Channel)repeatedlytoselect

Page 9 - • Triggerlevel

Using the Oscilloscope 33 29BConfiguring trigger settings: video triggering Overview Thevideotriggertypeisdesignedtocapturethevideosignal

Page 10 - 5. Adjusting waveform scales

Using the Oscilloscope 35 30BSelecting the acquisition mode Overview Theacquisitionmodespecifieshowtheincominganalogsignalisdigitallysamp

Page 11 - Configurations

Using the Oscilloscope 37 32BViewing the system status Overview ThesystemstatusmenushowstheGDS‐122systemsettings.Panel operations1. Press

Page 12 - isbeing

TABLE OF CONTENTS 3 TABLE OF CONTENTS Safety Instructions...6 Getting Started...

Page 13

Using the Oscilloscope 39 6BMeasurements Overview Theadvancedmeasurementfunctionsallowyoutoautomaticallymeasurevariousparametersinawave

Page 14 - RUN/STOP

Using the Oscilloscope 41 34BRunning automatic measurements Overview Theautomaticmeasurementfunctionmeasurestheinputsignal’scharacteristics

Page 15 - 134H33.

Using the Oscilloscope 43 Move the cursor leftMove thecursor rightMove the horizontal position leftMove the horizontal position right Display overv

Page 16 - Triggering pointFalling edge

Using the Oscilloscope 45 7BAdvanced Viewings Overview Theadvancedviewingfunctionsallowyoutoclearlyobservespecifictypeofwaveformsand/or

Page 17 - 137H30.

Using the Oscilloscope 47 38BViewing waveforms in X-Y format Overview TheX‐YformatplotstheCH1inputasX‐axisandCH2inputasY‐axis.Thisdis

Page 18 - Configuring display settings

Using the Oscilloscope 49 40BViewing noisy signals Overview UsingtheAverageacquisitionmode,youcansmoothoutthedisplayedwaveformbyaveragi

Page 19 - Viewing the system status

Using the Oscilloscope 51 8BCalibration Overview TheselfcalibrationautomaticallyadjuststheGDS‐122internalparameters.Theprobecalibrationa

Page 20 - Running waveform maths

Using the Oscilloscope 53 9BSaving/Recalling Waves and Settings Overview TheGDS‐122cansaveorrecallfoursetsofwaveformsusingitsinternalme

Page 21 - Measurement items

Using the Oscilloscope 55 46BRecalling waveforms Overview UptofourwaveformscanbestoredinandrecalledfromtheGDS‐122internalmemory.Thes

Page 22 - CURS MEAS

Using the Oscilloscope 57 Turn CH1 on or off CH1/2 SETUP→F2(Channel) Select probe scaling CH1/2 SETUP→F3(Probe) Turn inversion on or off CH1/2 SETUP

Page 23 - TIME MODE

TABLE OF CONTENTS 5 Measuring Voltage ... 85 Measuring Current ...

Page 24 - DISP SET

Using the Oscilloscope 59 Select line display DISP SET→F1(Type) Select persistency DISP SET→F2(Persist) Select display format DISP SET→F3(Format) Se

Page 25 - Viewing noisy signals

Using the Oscilloscope 61 11BUsing the Software Overview TheGDS‐122PCsoftware,includedintheCD‐ROM,allowsyoutoviewthewaveformsinyourf

Page 26 - FUNCTION

Using the Oscilloscope 63 ChangetheinstallationdirectoryifnecessaryandclickNext. ClickInstalltostartinstallingthesoftware.

Page 27 - WAVE SAVE

Using the Oscilloscope 65 61BActivating the software and connecting the GDS-122 Overview ActivatethesoftwareandconnecttheGDS‐122toitproperl

Page 28

Using the Oscilloscope 67 Acquiring data Inthesoftware,selectCommunications–GetDatafromthemenu.Alternatively,youmayclicktheGetdata

Page 29 - GDS-122 User Manual

Using the Oscilloscope 69 Turning the grid on or off Toturnonoroffthegrid,selectView>GridlinesfromthemenuorclicktheGridlinesic

Page 30 - Horizontal

Using the Oscilloscope 71 63BViewing the waveforms Overview Thissectionintroduceshowtomodifythewaveformsettingsforbetterviewings. • Se

Page 31 - Installing the software

Using the Oscilloscope 73 2. Holdthemouseanddragthewaveformsideways. Changing the vertical position Clickthechannellabelattheleft

Page 32 - • Uninstallingthesoftware

Using the Oscilloscope 75 64BUsing the cursor measurements Overview Thissectionintroduceshowtousecursormeasurementsinthesoftwarescreen.

Page 33

Using the Oscilloscope 77 65BSaving waveforms Overview YoucansavethewaveformsintothePCintwoways.Fordetailsofrecallingthem,seepage19

Page 34 - Configuring the screen

Safety Instructions 7 • Donotperformmeasurementsatapowergeneratingsourceorbuildinginstallationsite(seenotebelow).• Theinstrument

Page 35

Using the Oscilloscope 79 66BRecalling waveforms Overview YoucanrecallthewaveformsfromthePCintwoways.Fordetailsofsavingthem,seepage

Page 36 - Viewing the waveforms

Using the Oscilloscope 81 3. SelecttheViewSetting. Redraw graph according to sample data: TheGDS‐122refreshesthewaveformandadjustits

Page 37

Using the Multimeter 83 USING THE MULTIMETER ThischapterdescribesthemultimeterfunctionalitiesintheGDS‐122.Functionalitiesincludesthreema

Page 38

Using the Multimeter 85 13BMeasuring Voltage DC voltage specifications (details: page206H98)Range Accuracy Max input 400mV,4V,400V±(1%+1digit)

Page 39 - Saving waveforms

Using the Multimeter 87 14BMeasuring Current DC current specifications (details: page208H98)Range & Accuracy Max input 40mA±(1%+1digit)400

Page 40 - Printing out waveforms

Using the Multimeter 89 15BMeasuring Impedance Impedance specifications (details: page210H98)Range & Resolution 400Ω±(1%+3digits)4k,40k,4

Page 41 - Accessing the Help

Using the Multimeter 91 16BMeasuring Diode Range 0Vto1.5VPanel operations1. PresstheRswitch.Ifawarningmessageappears,pressanykeyto

Page 42 - MULTIMETER

Using the Multimeter 93 18BMeasuring Capacitance Continuity specifications Range 51.2nFto100uF±(3%+3digits)Panel operations1. PresstheRsw

Page 43 - Measuring Voltage

Faq 95 FAQ Power Q • TheGDS‐122doesnotpowerup.• TheGDS‐122stoppedworkingafterashortperiodoftime. AThebatterymayneedrechar

Page 44 - Measuring Current

Specifications 97 SPECIFICATIONS Conditions for specifications Thefollowingspecificationsareapplicablewhenthesetwoconditionsaremet:• Th

Page 45 - Measuring Impedance

Getting Started 9 GETTING STARTED ThischaptergivesyouanoverviewofwhattheGDS‐122isabout,whatitemsareincludedinthepackage,andhow

Page 46 - Measuring Continuity

Specifications 99 400mA range: 100uA 20A range: 10mA ACA Accuracy 40mA range: ±1.5%±3 digit 400mA range: ±2 %±1 digit 20A range: ±5%±3 digits Res

Page 47 - Measuring Capacitance

Index 101 INDEX ACcouplingtrigger ... 32vertical... 24ACAm

Page 48

Index 103 operationenvironment... 7OSCoptionkey... 60oscilloscopespecifications ...

Page 49 - SPECIFICATIONS

Getting Started 11 1BMain Features Oscilloscope • Dualchannel• 20MHzbandwidth• 100MS/sreal‐timesamplingrate• ≤17.5nsrisingtime• 5

Page 50 - CONFORMITY

Getting Started 13 MENU key + Up/Down keys DSO Activatesthesidemenuandselectsthemenuitems.RUN/STOP key DSO Manuallyturnson(run)oroff

Page 51 - Index

Using the Oscilloscope 15 USING THE OSCILLOSCOPE ThischapterdescribestheoscilloscopefunctionalitiesintheGDS‐122:settingitupandmeasuring

Page 52

Using the Oscilloscope 17 powercordifthelevelis<25%. > 75% 75% 50% 25% < 25% Switching the operation mode Ifthemultimetersc

Comments to this Manuals