Digital Storage Oscilloscope GBS-1000 Series PROGRAMMING MANUAL GW INSTEK PART NO. 82BS-12040M01 ISO-9001 CERTIFIED MANUFACTURER
GBS-1000 Programming Manual 10
COMMAND SET 11 COMMAND SET Command List System *IDN?... ...17 *LRN?...
GBS-1000 Programming Manual 12 Display :DISPlay:ACCumulate ... 36 :DISPlay:CONTrast ...
COMMAND SET 13 Measure :MEASure:DELAY1 ... 54 :MEASure:DELAY2 ...
GBS-1000 Programming Manual 14 Memory :MEMory<X>:RECall:SETup ... 70 :MEMory<X>:RECall:WAVeform .
COMMAND SET 15 Time :TIMebase:DELay ... 86 :TIMebase:SCALe ...
GBS-1000 Programming Manual 16 Command Syntax Compatible standard IEEE488.2, 1992 (fully compatible) SCPI, 1994 (partially compatible) Comm
COMMAND SET 17 System Commands *IDN?...17 *LRN?... ...
GBS-1000 Programming Manual 18 0;SOURce 0;ADVance:DELay 1.000E-07;EVENt 3;LEVel 1.480E+00;MODe 0;TYPe 0;PULSe:TIMe 1.000E+01;MODe: 1;TV:FIELd 1;LI
COMMAND SET 19 *RCL Set Description Recalls a set of panel setting from one of the twenty internal memories, S1 to S20. Same as: Save/Recall key
This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual may be photocopied,
GBS-1000 Programming Manual 20 Acquisition Command :ACQuire:AVERage ... 20 :ACQuire:LENGth ..
COMMAND SET 21 :ACQuire:LENGth SetQuery Description Selects or returns the memory length. Same as: Acquire key → F5 Syntax < Long > <
GBS-1000 Programming Manual 22 :ACQuire:MEMory Query Description Returns the total waveform data from the acquisition memory. Syntax < Long &
COMMAND SET 23 Auto Set Command :AUToset Set Description Runs Auto Set (automatically configures horizontal scale, vertical scale, trigger accord
GBS-1000 Programming Manual 24 Channel / Math Command :CHANnel<X>:BWLimit ... 24 :CHANnel<X
COMMAND SET 25 :CHANnel<X>:COUPling SetQuery Description Selects or returns the coupling mode for each channel. Same as: Channel key → F1
GBS-1000 Programming Manual 26 :CHANnel<X>:EXPand SetQuery Description Sets the expansion mode as from ground or from center for a selected
COMMAND SET 27 :CHANnel<X>:MATH SetQuery Description Selects or returns the math operation. Same as: Math key → F1 Syntax < Long > &
GBS-1000 Programming Manual 28 :CHANnel<X>:OFFSet SetQuery Description Sets or returns the offset level for each channel. The offset level
COMMAND SET 29 :CHANnel<X>:SCALe SetQuery Description Sets or returns the vertical scale for each channel. The scale is dependent on the p
TABLE OF CONTENTS 3 Table of Contents CONFIGURATION ... 4 Interface Overview ...
GBS-1000 Programming Manual 30 Data Log Commands :DATALOG:STATE ... 30 :DATALOG:SOURce ...
COMMAND SET 31 4 Sets CH4 as the source channel 5 Sets Math as the source channel Example :DATALOG:SOUR 1 Set source as CH1. :DATALOG:SAVe SetQu
GBS-1000 Programming Manual 32 Syntax < Long > < Short > :DATALOG:DURation <NR1> :DATALOG:DURation? :DATALOG:DUR <NR1>
COMMAND SET 33 Cursor Command :CURSor:X<X>Position ... 33 :CURSor:Y<X>Position ...
GBS-1000 Programming Manual 34 Parameter <X> Cursor 1 or 2 <NR1> Cursor position 1 Cursor V1 1 ~ 199 1 ~ 199 point 2 Cursor V2 Exa
COMMAND SET 35 :CURSor:SOURce SetQuery Description Selects or returns the cursor source channel. Same as: Cursor key →F1 (Source) Syntax < Lon
GBS-1000 Programming Manual 36 Display Command :DISPlay:ACCumulate ... 36 :DISPlay:CONTrast ...
COMMAND SET 37 :DISPlay:CONTrast SetQuery Description Sets or returns the display contrast level. Same as: Display key → F4 (Contrast) Syntax &l
GBS-1000 Programming Manual 38 :DISPlay:WAVEform SetQuery Description Sets or returns the display waveform type. Same as: Display key → F1 (Type
COMMAND SET 39 Go-NoGo Command :GONogo:FUNction ... 39 :GONogo:CLEar ...
GBS-1000 Programming Manual 4 CONFIGURATION This chapter describes how to configure GBS-1000 remote control interface. GBS-1000 series overview
GBS-1000 Programming Manual 40 :GONogo:CLEar Set Description Clears Go-No Go test total number/ failure number counter on the display. Same as:
COMMAND SET 41 :GONogo:NGCount? Query Description Returns Go-No Go test total and fail count. Same as: Utility key → F5 (More) → F3 (Go-NoGo Men
GBS-1000 Programming Manual 42 :GONogo:SOURce SetQuery Description Sets or returns Go-No Go test source channel. Same as: Utility key → F5 (More
COMMAND SET 43 :TEMPlate:MAX SetQuery Description Sets or returns Go-No Go Max template. Same as: Utility key → F5 (More) → F3 (Go-NoGo Menu) →
GBS-1000 Programming Manual 44 :TEMPlate:MIN SetQuery Description Sets or returns Go-No Go Min template. Same as: Utility key → F5 (More) → F3 (
COMMAND SET 45 :TEMPlate:MODe SetQuery Description Sets or returns Go-No Go test template mode. Same as: Utility key → F5 (More) → F3 (Go-NoGo M
GBS-1000 Programming Manual 46 :TEMPlate:POSition:MAX SetQuery Description Sets or returns Go-NoGo Max template position. Same as: Utility key →
COMMAND SET 47 :TEMPlate:POSition:MIN SetQuery Description Sets or returns Go-NoGo Min template position. Same as: Utility key → F5 (More) → F3
GBS-1000 Programming Manual 48 :TEMPlate:SAVe:AUTo Set Description Saves Go-NoGo test Auto template. Same as: Utility key → F5 (More) → F3 (Go-N
COMMAND SET 49 :TEMPlate:TOLerance SetQuery Description Sets or returns Go-NoGo Auto template tolerance. Same as: Utility key → F5 (More) → F3 (
CONFIGURATION 5 Interface Overview Rear panel
GBS-1000 Programming Manual 50 Hardcopy Command :COPY…………… ... 50 :HARDcopy:INKSaver ..
COMMAND SET 51 :HARDcopy:LAYout SetQuery Description Selects or returns printout color in Hardcopy Printer mode. Same as: Utility key → F1(Hardc
GBS-1000 Programming Manual 52 :HARDcopy:RATio SetQuery Description Selects or returns Hardcopy printout ratio relative to the paper size. Same
COMMAND SET 53 Measure command :MEASure:DELAY1 ... 54 :MEASure:DELAY2 ...
GBS-1000 Programming Manual 54 :MEASure:DELAY1 SetQuery Description Sets or returns the first source channel for the delay automatic measurement.
COMMAND SET 55 :MEASure:DELAY2 SetQuery Description Sets or returns the second source channel for the delay automatic measurement. Same as: Meas
GBS-1000 Programming Manual 56 :MEASure:FFFDelay Query Description Returns the delay between the first falling edge of source1 and the first fal
COMMAND SET 57 :MEASure:FOVShoot Query Description Returns fall overshoot amplitude in percentage. Same as: Measure key → F1~F5 → F3 (FOVShoot)
GBS-1000 Programming Manual 58 :MEASure:FREQuency? Query Description Returns the frequency value. Same as: Measure key → F1~F5 → F3 (Frequency)
COMMAND SET 59 :MEASure:FRRDelay Query Description Returns the delay between the first rising edge of source1 and the first rising edge of sourc
GBS-1000 Programming Manual 6 Functionality check Run this query command via the terminal. *idn? This should return the Manufacturer, Model number
GBS-1000 Programming Manual 60 :MEASure:LFRDelay Query Description Returns the delay between the first falling edge of source1 and the last risi
COMMAND SET 61 :MEASure:LRRDelay Query Description Returns the delay between the first rising edge of source1 and the last rising edge of source
GBS-1000 Programming Manual 62 :MEASure:PDUTy? Query Description Returns the positive duty cycle ratio. Same as: Measure key → F1~F5 → F3 (DutyC
COMMAND SET 63 :MEASure:PWIDth? Query Description Returns the first positive pulse width. Same as: Measure key → F1~F5 → F3 (+Width) Syntax <
GBS-1000 Programming Manual 64 :MEASure:ROVShoot Query Description Returns rise overshoot amplitude in percentage. Same as: Measure key → F1~F5
COMMAND SET 65 :MEASure:SOURce SetQuery Description Selects the measurement channel. Same as: Measure key → F1~F5 → F1, F2 Syntax < Long >
GBS-1000 Programming Manual 66 :MEASure:VAVerage Query Description Returns the average voltage. Same as: Measure key → F1~F5 → F3 (Vavg) Syntax
COMMAND SET 67 :MEASure:VLO Query Description Returns the global low voltage. Same as: Measure key → F1~F5 → F3 (Vlo) Syntax < Long > <
GBS-1000 Programming Manual 68 :MEASure:VMAX Query Description Returns the maximum amplitude. Same as: Measure key → F1~F5 → F3 (Vmax) Syntax &l
COMMAND SET 69 :MEASure:VPP Query Description Returns the peak-to-peak amplitude (difference between maximum and minimum amplitude) Same as: Mea
CONFIGURATION 7 USB interface Configuration USB configuration PC side connector Type A, host GBS-1000 side connector Type B, slave Speed 1.1/2.0
GBS-1000 Programming Manual 70 Memory (Save/Recall) Command :MEMory<X>:RECall:SETup ... 70 :MEMory<
COMMAND SET 71 :MEMory<X>:RECall:WAVeform Set Description Recalls a waveform from the internal memory and saves to a reference waveform. Sa
GBS-1000 Programming Manual 72 :MEMory<X>:SAVe:WAVeform Set Description Saves a reference waveform to internal memory. Same as: Save/Recall
COMMAND SET 73 Syntax < Long > < Short > :ref<x>:display <Boolean> :ref<x>:display? :ref<x>disp <Boolean&g
GBS-1000 Programming Manual 74 :REF<X>:SAVe Set Description Saves an input signal as a reference waveform. Same as: Save/Recall key → F4(Sa
COMMAND SET 75 :USB:RECall:WAVeform Set Description Recalls a waveform from the USB and saves to a reference waveform. (Note: Only the last saved
GBS-1000 Programming Manual 76 :USB:SAVe:SETup Set Description Saves the current setup to the USB flash drive. Same as: Save/Recall key → F3(Save
COMMAND SET 77 Run/Stop Commands :RUN….. ………………………………………………………………77 :STOP…. ………………………………………………………………77 :RUN Set Description Controls the RUN s
GBS-1000 Programming Manual 78 Trigger Commands :TRIGger:COUPle ... 78 :TRIGger:FREQuency
COMMAND SET 79 :TRIGger:FREQuency SetQuery Description Returns the readout value of the trigger frequency counter. Syntax < Long > < Sho
GBS-1000 Programming Manual 8 RS-232C Interface Configuration RS-232C configuration Connector DB-9, Male Baud rate 2400, 4800, 9600, 19200, 38400
GBS-1000 Programming Manual 80 1 Auto 2 Normal 3 Single Example :trigger:mode 1 Sets the trigger mode to AUTO. :TRIGger:NREJ SetQuery Descript
COMMAND SET 81 1 > 2 = 3 ≠ Example :trigger:pulse:mode 1 Sets the triggering condition to “>”. :TRIGger:PULSe:TIMe SetQuery Description
GBS-1000 Programming Manual 82 2 High frequency rejection Example :trigger:reject 0 Turns frequency rejection off. :TRIGger:SLOPe SetQuery Descr
COMMAND SET 83 Example :trigger:source 0 Sets the trigger source to CH1. :TRIGger:TYPe SetQuery Description Sets or queries the trigger type. Sam
GBS-1000 Programming Manual 84 :TRIGger:VIDeo:LINe SetQuery Description Sets or queries which specific line to trigger on. Same as: Trigger MENU
COMMAND SET 85 :TRIGger:VIDeo:TYPe SetQuery Description Sets or queries the video trigger standard. Same as: Trigger MENU key → F3 (Standard). (N
GBS-1000 Programming Manual 86 Time (horizontal) Commands :TIMebase:DELay ... 86 :TIMebase
COMMAND SET 87 5ns 5e-9 25us 25e-6 100ms 100e-3 10ns 10e-9 50us 50e-6 250ms 250e-3 25ns 25e-9 100us 100e-6 500ms 500e-3 50ns 50e-9 250us 250e-
GBS-1000 Programming Manual 88 :TIMebase:WINDow:DELay SetQuery Description Sets or returns the zoomed window horizontal position in seconds. Same
CONFIGURATION 9 Range None, Odd, Even 9. Connect the RS-232C cable to the rear panel port: DB-9 male connector. Pin assignment 1 2 3 4 5
Comments to this Manuals